Add SNMP Devices

Add SNMP devices when you already know the addresses you want to poll, such as a core switch, an edge router, a firewall, or a rack PDU. The Add SNMP devices wizard walks you through picking an agent, listing targets, entering credentials, and choosing a device profile and polling interval. From there the agent polls each device on a schedule and reports its metrics to KloudMate.

To sweep a subnet and monitor whatever answers instead, use Discover devices.

  • A KloudMate Agent running on a Linux host or in Docker, with network access to the devices. Kubernetes agents can’t poll SNMP. Install the Linux agent or Docker agent if you don’t have one.
  • SNMP enabled on each device, with a community string (v1/v2c) or a v3 USM user.
  • The agent host’s IP address allowed in the device’s SNMP access list. If the device restricts SNMP by source IP and the agent isn’t on the list, no metrics come back.
  • UDP port 161 reachable from the agent to each device (the SNMP default).

In Network Monitoring, open the Add menu and choose SNMP device. The wizard has six steps.

Step 1 of the Add SNMP devices wizard, showing the six-step progress bar and the Collector Agent dropdown

Pick the Linux or Docker agent that will poll the devices. It needs a network path to every target in this batch. The list shows only eligible agents. If it’s empty, install one first from the link in the step.

List the devices to poll. Paste one target per line into the box, using an IP, a CIDR block, a last-octet range, or a hostname. Then select Expand & add to turn them into rows:

10.0.0.1
10.0.10.0/24
10.0.1.1-50
core-sw-01.example.com

Each row takes an endpoint and a credential. Leave the credential set to Default to use the profile you mark as default in the next step, or pick a specific one per device.

Create one or more credential profiles that your targets reference, so devices that share a community or v3 user reuse the same entry.

  • v1 or v2c: enter the community string.
  • v3 (USM): enter a username and security level (noAuthNoPriv, authNoPriv, or authPriv). For authNoPriv and authPriv, choose an auth protocol (MD5, SHA, SHA224, SHA256, SHA384, or SHA512) and password. For authPriv, also choose a priv protocol (DES, AES, AES192, or AES256) and password.

You enter these values directly. Mark one profile as the default for new targets.

The Credentials step with a credential profile: profile name, SNMP version, and community string fields, plus a default-credential selector

A device profile decides which tables the agent walks and what metrics it emits. Choose how to match one:

  • Auto-detect (recommended): the agent reads the device’s sysObjectID and picks the matching vendor profile. This covers most Cisco, Juniper, Arista, HPE, Aruba, Dell, Fortinet, MikroTik, F5, and APC gear out of the box.
  • Pick from catalog: choose a specific profile by name.
  • Custom: name a profile you’ve defined.

The Profile step with the Auto-detect, Pick from catalog, and Custom options, and the optional Extra capabilities checkboxes for BGP peers, MPLS L3VPN, LLDP neighbours, and IP SLA

Polling interval sets how often the agent polls the devices in this batch: Every 60 seconds (the default), Every 5 minutes, or Every 15 minutes. A slower interval suits devices that don’t need minute-level detail, such as access switches and PDUs. Every metric from the device, including km_snmp_up, arrives at that pace. MAC address tables are read every 5 minutes, or at the device’s interval when it’s longer.

Device status follows the interval. A device shows as Not reporting only after its last data is more than three polling intervals old, and never sooner than 5 minutes, so a device polled every 15 minutes isn’t flagged between polls.

The 5- and 15-minute options need agent 2.11.0 or later. On an older agent the field stays at 60 seconds. To change the interval of devices you’ve already added, edit them from Configure.

Under Extra capabilities (optional), turn on tables that only matter for routers and layer-3 devices. Leave them off for plain hosts and switches, where they add polling work with no benefit.

CapabilityWhat it collects
BGP peersPeer state per neighbour, for edge and ISP routers.
MPLS L3VPNVRF operational status and route counts.
IP SLACisco IP SLA reachability probes, for per-WAN ISP verdicts.

LLDP and CDP neighbours aren’t on this list because the agent collects them from every device. See Neighbours and MAC address tables.

Add key-value tags such as site, group, or role, or anything you use to organize devices. They apply to every device in this batch and drive the filtering and grouping in Network Monitoring. Grouping the Overview’s Devices table by site or role, for example, only works if your devices carry that tag.

Check the staged devices, then select Apply configuration. On agent 2.11.0 or later, a change that only adds, edits, or removes SNMP devices reaches the running agent without restarting data collection. The exception is the first SNMP device on an agent, or removing the last one. Older agents briefly restart data collection on every save, so the wizard applies every device in the run together to keep the interruption short.

Within a few minutes the devices appear on the All devices tab with an Up status, and their metrics are queryable. The agent emits, per interface:

  • snmp_interface_in_octets, snmp_interface_out_octets: throughput in bytes
  • snmp_interface_in_errors, snmp_interface_out_errors
  • snmp_interface_in_discards, snmp_interface_out_discards
  • snmp_interface_oper_status, snmp_interface_admin_status (2 means down)
  • snmp_interface_speed

Per device, you get snmp_device_uptime, snmp_cpu_usage, and snmp_memory_usage (plus snmp_memory_used, _free, and _total). The agent’s own reachability check is km_snmp_up, which reads 1 when the device answers and 0 when it doesn’t. Turn on capabilities and you also get snmp_bgp_peer_state, snmp_mpls_l3vpn_vrf_oper_status, snmp_isp_reachability, and related metrics.

If a device stays Down or never appears, work through the checklist in Manage and troubleshoot.

On agent 2.11.0 or later, the agent reads the LLDP and CDP neighbour tables of every SNMP device, including devices found by discovery. There’s nothing to turn on. Each neighbour becomes a snmp_topology_link series with neighbor_device, neighbor_port, local_port_num, and discovery_protocol (lldp or cdp), and these series draw the Topology map. A neighbour that speaks both protocols is reported once by each, and the map shows them as one link.

Agents older than 2.11.0 don’t collect CDP, and they collect LLDP only for devices that were set up with the LLDP neighbours capability.

Switches also report their MAC address tables, every 5 minutes or at the device’s polling interval when that’s longer:

  • snmp_interface_mac_count: how many addresses each port has learned, across all VLANs.
  • snmp_fdb_entry: one series per learned address, with mac_address, interface_name, vlan, and ip_address when the device’s own ARP table has it.

On agent 2.11.0 or later, the agent reads every VLAN’s addresses. It uses the Q-BRIDGE-MIB table where the switch has one. On a Cisco switch without it, the agent walks each active VLAN with community@<vlan> on v1 and v2c, or the vlan-<id> context on v3. Other switches report the plain BRIDGE-MIB table, which has no vlan. Older agents read only the plain table, which on Cisco covers only the default VLAN.

Large tables have limits. A device with more than 5,000 learned addresses reports no snmp_fdb_entry series, and per-port counts stop past 20,000 table rows. These tables feed the port and host views described in Using Network Monitoring.

The device drawer’s Overview tab has a Sensors panel with the device’s temperature, fan, power, and voltage readings. Sensors in a fault state, such as a failed fan or a power supply that’s off, are flagged and listed first within their type.

The panel reads the sensor metrics that the device’s profile already collects: Cisco environmental and FRU status, ENTITY-SENSOR-MIB sensors, and the Huawei, Aruba, MikroTik, and Dell OS10 sensor tables. If the profile collects none of these, the panel stays empty. Readings whose unit isn’t fixed by the MIB, such as volts and watts, are shown as the device reports them.