Skip to content

Panel Options

Panel options control how a panel draws the values its queries return: the unit and number style, colors, thresholds, value mappings, and data links. You set them in the panel editor, in the settings pane on the right.

The settings pane has tabs for Options, Transform, and Overrides:

  • Options holds the settings for the whole panel. A setting here applies to every series, column, or tile the panel draws.
  • Transform reshapes the query results before the panel draws them, for example to join two queries into one table or to reorder table columns. See Transformations.
  • Overrides holds rules that change settings for only the fields a rule matches, such as one series on a chart or one column in a table. See Overrides.

Alerts List and Issues List panels have only the Options tab, with the Panel and Time range sections.

The Options tab in the panel editor

Every panel type that draws values has a Standard options section on the Options tab. Some of its options only appear on the panel types that can use them:

OptionWhat it doesPanel types
Display nameRenames the series, column, or tile. Leave it empty to keep the name from the query.All except Alerts List and Issues List
RangeSets the Min and Max a value is drawn against, such as the ends of a gauge’s arc.Stats, Gauge, Table
FormatSets the unit and how numbers are written. Histogram and Heatmap panels have Bucket format instead, which formats the bucket boundaries.All except Alerts List and Issues List
Color schemePicks how values or series are colored.TimeSeries, Stats, Gauge, Table
No-data valueSets what a tile shows when its query returns no value, such as 0.Stats

A Display name set on the Options tab renames every series in the panel. To rename a single series or column, set Display name in an override rule instead.

Options apply to everything, overrides to what they match

Section titled “Options apply to everything, overrides to what they match”

An option you set on the Options tab applies to every series, column, or tile in the panel. An override rule applies only to the fields it matches. When both set the same option for a field, the override wins.

For example, set Unit to Milliseconds on the Options tab, then add an override that sets Bytes for the heap_used series. That series is written in bytes, and every other series keeps milliseconds.

When you haven’t set a unit, the panel uses the unit the metric declares. A metric reported in bytes is written in bytes and a metric reported in seconds is written as a duration, with no setup. Set Unit only when the data doesn’t declare one or you want a different one. See Format values and units.

When the data source already sets something on a field, such as a unit the metric declares, the section on the Options tab or the property row in an override shows a From data source chip. Hover the chip to see which fields it applies to. A value you set replaces the data source’s. Data links are the exception: links on the Options tab are added to the data source’s links. See Data links.

The Options tab shows these sections, in this order:

Panel typeSections
TimeSeriesPanel, Standard options (Display name, Format, Color scheme), Axes, Legend, Graph options, Tooltip, Axis placement, Threshold, Data links & actions, Value mappings, Annotations, Time range
StatsPanel, Standard options (Display name, Range, Format, Color scheme), Calculations, Rename, Stat options, Threshold, Data links & actions, Value mappings, Time range
GaugePanel, Standard options (Display name, Range, Format, Color scheme), Calculations, Gauge, Threshold, Data links & actions, Value mappings, Time range
TablePanel, Standard options (Display name, Range, Format, Color scheme), Cell options, Column layout, Value mappings, Threshold, Data links & actions, Time range
Pie ChartPanel, Standard options (Display name, Format), Value options, Display, Legend, Time range
Bar ChartPanel, Standard options (Display name, Format), Display, Axes, Legend, Time range
HistogramPanel, Standard options (Display name, Bucket format), Axes, Legend, Time range
HeatmapPanel, Standard options (Display name, Bucket format), Display, Time range
TextPanel, Standard options (Display name, Format), Content
Alerts List, Issues ListPanel, Time range

The options specific to one panel type are covered on that panel’s page under Adding a Panel.